Do you have questions? Our community may have already answered them!
Connect with others in our support forum.
Kinco EtherCAT bus coupler (with end cover) for Kinco RP20 modules
- EtherCAT, DC sync from 1 ms
- Up to 16 RP20 modules
- 2 × RJ45 (EtherCAT IN/OUT)
- Module scan in CODESYS
- −20 °C to +55 °C
€108.80*
% €108.80* (0% saved)In stock
Lieferzeit: 3 bis 5 TageCompatible expansions
Available in 30 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Customers also bought
Customers also bought
Available, delivery time: 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available, delivery time: 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Customers also viewed
Customers also viewed
Available, delivery time: 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available, delivery time: 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
You want to connect I/O where the signals originate, and your controller is an EtherCAT master? The Kinco RP20C-ECT turns up to 16 modules of the RP20 series into an EtherCAT remote I/O station. Instead of wiring every sensor individually back to the control cabinet, you only run one network cable and the 24 V supply to the station.
🏭 Typical Applications
Remote I/O for the Kinco AK840M: The AK840M controls EtherCAT servo axes and additionally connects I/O stations via the RP20C-ECT, on the same bus as the drives.
Decentralised stations on the machine: Conveyor lines, gantries or dosing stations get their I/O right on site. Up to 100 m between two bus nodes.
Additional I/O on an existing EtherCAT controller: Running out of channels? The RP20C-ECT joins the existing line as another node, the controller stays.
Mixed signals at one station: Digital, analogue and temperature in any combination, up to 16 modules per coupler.
🖥️ Key Technical Specs
Expansion: up to 16 RP20 modules via the internal K-BUS (100 Mbit/s).
Supply: 24 V DC ±20 % (19.2 – 28.8 V DC), own consumption 2.5 W, max. 20 W at full load.
Bus current for the modules: 2.0 A at 5 V, max. 1.6 A at 55 °C.
Supply input protection: overcurrent, reverse polarity, surge.
Diagnostics: LEDs PWR, RUN, ERR and SF; error codes in the object dictionary (0x3010, 0x3012), readable in CODESYS via “Online CoE”.
Service: USB-C for firmware update.
🔌 EtherCAT Interface
Protocol: EtherCAT slave at 100 Mbit/s.
Synchronisation: DC sync (minimum cycle time 1 ms), SM sync and FreeRun.
Connection: EtherCAT IN and EtherCAT OUT via 2 × RJ45, pin assignment according to the Ethernet standard (ISO/IEC 8802-3). Cable at least CAT5, CAT5e recommended.
Cable length: up to 100 m between two EtherCAT nodes.
Device description: one ESI file (XML) for the coupler and all RP20 modules.
🔗 Compatibility and Matching Modules
The RP20C-ECT works with any EtherCAT master that imports ESI files. In the manual, Kinco shows commissioning with CODESYS V3.5.19. The matching controller from the Kinco range is the AK840M with native EtherCAT.
RP20 digital modules: 8 or 16 channels, transistor or relay.
RP20 analogue modules: voltage and current, inputs and outputs.
RP20 temperature modules: Pt100, Pt1000, Cu50 or thermocouple.
RP20-PW power supply module: additional bus current for large stations.
If your controller uses CANopen, the RP20C-CAN is the matching coupler.
⚠️ Good to Know Before Commissioning
Modules by scan or by hand: With the coupler connected, CODESYS reads in the modules by scan. If you add them by hand, the order must match the actual mounting order, otherwise no communication is established.
Check the bus current: Each RP20 module draws 135 to 160 mA from the K-BUS. 16 digital modules already add up to about 2.2 A, more than the coupler's 2.0 A. If the total exceeds 2.0 A (1.6 A at 55 °C), add an RP20-PW power supply module to the station.
🏷️ Manufacturer and Standards
Kinco Automation develops PLCs, HMIs and drive technology. The RP20C-ECT is CE certified. EMC immunity according to IEC 61131-2, zone B: ESD 8 kV air and 4 kV contact, burst 2 kV on the supply port. Operation −20 °C to +55 °C, storage −40 °C to +70 °C, 10 to 95 % relative humidity non-condensing, up to 2,000 m altitude.
🔧 Mounting and Scope of Delivery
Mounting: 35 mm DIN rail (1 mm rail thickness) with spring latch. The modules snap on sideways via upper and lower guides. End clamps on both sides keep the station from shifting.
Supply pass-through: two internally connected 24 V terminal groups.
Dimensions: 24.3 × 100 × 80 mm (W × H × D), approx. 120 g, passive cooling, IP20.
Scope of delivery: RP20C-ECT with end cover. Kinco provides the manual and ESI file for download.
Compatible expansions
Available in 30 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Technical Specifications
0 of 0 reviews
Login
Aktive Kühlung oder Lüfter bedeutet, das Gerät hat einen eingebauten Lüfter zur Kühlung. Ein aktiver Lüfter verursacht zusätzliche Geräuschemissionen.
PROFINET / EtherCAT / EtherNet/IP: Real-time capable Ethernet protocols – direct connection to Siemens S7, Beckhoff TwinCAT, Allen-Bradley and others.
Modbus TCP/RTU: Simple, open standard – supported by virtually every PLC and many frequency inverters.
The protocol determines which controller can integrate the module directly without a gateway.
IP20: Protection against finger contact – no dust or water protection. Standard for control cabinet installation.
IP67: Fully dustproof and waterproof during temporary submersion (1 m, 30 min). Suitable for field mounting directly on machines.