Filter
–
Larger base units for modular compact PLCs
22 digital inputs 24 VDC (PNP)
8 digital outputs transistor 24 VDC12 digital outputs relay2 x RS-485 (supports Modbus RTU)
Programming Software: Kinco Builder
(English, Ladder Diagram KOP / AWL, free download)
Programming you can the Kinco K2 with the free Kinco-Builder programming software (available as download a little further down this page).
Scope of delivery: PLC
- Available
- Delivery Time : 3 bis 5 Tage
- Product Benefits 1: 6 x Analogeingang (mA, V)
- Product Benefits 2: 2 x Analogausgang (mA, V)
- Product Benefits 3: 22 x Digitaleingang 24 VDC (PNP)
- Product Benefits 4: 20 x Digitalausgang (Transistor)
- Product Benefits 5: 2 x serielle Schnittstelle (RS-485)
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Your system has more sensors and actuators than a compact PLC with 24 channels can handle? The Kinco K608-40 comes with 24 digital inputs and 16 outputs, plus two BD slots for CAN, additional interfaces or I/O. Many machines manage without a single expansion module.
🏭 Typical applications
Multi-station machines: assembly, test and packaging lines with many limit switches, light barriers and valves.
Drives via CANopen: with the KB6-CAN board you control up to 64 CANopen nodes, or Kinco servo and stepper drives via the Kinco motion protocol.
Positioning: the transistor variants output pulse and direction on four channels, three of them up to 200 kHz.
Building services: pumps, ventilation and inverters via Modbus RTU, visualisation via Modbus TCP.
⚙️ Four variants
K608-40DT: 24 V DC supply, 16 PNP transistor outputs
K608-40AT: 100 – 240 V AC supply, 16 PNP transistor outputs
K608-40DR: 24 V DC supply, 16 relay outputs
K608-40AR: 100 – 240 V AC supply, 16 relay outputs
💡 The relay variants have no pulse outputs. For positioning tasks, choose DT or AT.
⚡ Inputs and outputs
24 digital inputs 24 V DC, wired as PNP or NPN, optically isolated, input delay below 40 µs (high-speed channels below 5 µs).
PNP transistor outputs: 500 mA per channel at 24 V DC, protected against short circuit, inductive loads and reverse polarity.
Relay outputs: 2 A per contact at 30 V DC or 250 V AC, max. 8 A per group of 4 channels, electrical life 100 000 operations at rated load.
High-speed counters: 4 channels, HSC0 and HSC1 up to 200 kHz, HSC2 and HSC3 up to 20 kHz single-phase or 10 kHz A/B. 4 edge interrupts on I0.0 to I0.3.
Pulse outputs (transistor variants only): 4 channels for PTO (pulse/direction) and PWM, PTO0 to PTO2 up to 200 kHz, PTO3 up to 10 kHz. Positioning instructions and a follow function are included in KincoBuilder.
🔌 Communication
Ethernet 10/100 Mbit/s: Modbus TCP client and server, free communication via TCP and UDP, program upload/download and firmware update over the network.
2 × RS-485, galvanically isolated: 1200 to 115 200 bit/s, Modbus RTU master or slave, free protocol and programming on both ports. Up to 32 devices per port.
🧩 Expansion
Two BD slots take expansion boards directly on the CPU. BD0 accepts communication and I/O boards (KB6-CAN, KB6-2COM, KB6-4DI, KB6-4DO), BD1 accepts I/O boards only (KB6-4DI, KB6-4DO). On top, up to 14 expansion modules connect to the local bus. The CPU supplies them with up to 1500 mA at 5 V and 360 mA at 24 V. From about 7 modules, or when the current budget runs out, you add the K680 power supply to the module row.
💻 Programming and memory
You program the controller with KincoBuilder (IEC 61131-3) in ladder diagram (LD) or instruction list (IL), version V8.5.0.3 or later. The CPU offers 8k instructions of program memory and 20 kB of data memory (16 kB V area, 4 kB M area). 1000 standard instructions execute in 0.3 ms. On top come 256 timers, 256 counters, arrays with up to 1024 elements and a battery-backed real-time clock (deviation below 5 min per month at 25 °C). The V area and counter values are retained on power loss, and the battery is replaceable.
🔗 Compatible with Kinco K5
Terminal layout and power connection match the K5 series, existing K5 programs run without changes, and K5 expansion modules plug in directly. This lets you replace a K5 in the cabinet without rewiring or reprogramming.
🏷️ Manufacturer and standards
Kinco Automation, based in Shanghai and Shenzhen, develops controllers, HMIs and drive technology for international machine builders. The K608-40 is CE marked (EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019) and tested to GB/T 15969.3-2007, which is equivalent to IEC 61131-2:2007. Protection class IP20, operation from −10 °C to +55 °C, 10 % – 95 % relative humidity without condensation, altitude up to 2000 m.
🔧 Mounting
On 35 mm DIN rail or with M4 screws on the mounting plate. Dimensions 186 mm × 114 mm × 76 mm, the terminal blocks are pluggable.
- Available
- Delivery Time : 2-5 days
- Product Benefits 1: 24 DI / 16 DO
- Product Benefits 2: Modbus TCP & RTU
- Product Benefits 3: 2 BD slots
- Product Benefits 4: 4 × HSC up to 200 kHz
- Product Benefits 5: runs K5 programs directly