Filter
–
You need a controller for a machine with a manageable number of signals and want to expand later without replacing the PLC? The Kinco K606-24 comes with 14 digital inputs, 10 outputs, Ethernet and two galvanically isolated RS-485 ports, and grows with your system via one BD slot and up to 14 expansion modules.
🏭 Typical applications
Conveying and packaging: belts, diverters and feeders. The high-speed counters read encoders up to 200 kHz directly on the device.
Positioning with stepper or servo drives: the transistor variants output pulse and direction on four channels, three of them up to 200 kHz.
Pumps, fans and frequency inverters: control drives and meters directly via Modbus RTU on RS-485.
Connection to HMI and control system: Modbus TCP via Ethernet, for example to a Kinco HMI or a higher-level SCADA.
⚙️ Four variants
K606-24DT: 24 V DC supply, 10 PNP transistor outputs
K606-24AT: 100 – 240 V AC supply, 10 PNP transistor outputs
K606-24DR: 24 V DC supply, 10 relay outputs
K606-24AR: 100 – 240 V AC supply, 10 relay outputs
💡 The relay variants have no pulse outputs. For positioning tasks, choose DT or AT.
⚡ Inputs and outputs
14 digital inputs 24 V DC, wired as PNP or NPN, optically isolated, input delay below 40 µs (high-speed channels below 5 µs).
PNP transistor outputs: 500 mA per channel at 24 V DC, protected against short circuit, inductive loads and reverse polarity.
Relay outputs: 2 A per contact at 30 V DC or 250 V AC, max. 8 A per group of 4 channels, electrical life 100 000 operations at rated load.
High-speed counters: 4 channels, HSC0 and HSC1 up to 200 kHz, HSC2 and HSC3 up to 20 kHz single-phase or 10 kHz A/B. 4 edge interrupts on I0.0 to I0.3.
Pulse outputs (transistor variants only): 4 channels for PTO (pulse/direction) and PWM, PTO0 to PTO2 up to 200 kHz, PTO3 up to 10 kHz. Positioning instructions and a follow function are included in KincoBuilder.
🔌 Communication
Ethernet 10/100 Mbit/s: Modbus TCP client and server, free communication via TCP and UDP, program upload/download and firmware update over the network.
2 × RS-485, galvanically isolated: 1200 to 115 200 bit/s, Modbus RTU master or slave, free protocol and programming on both ports. Up to 32 devices per port.
🧩 Expansion
One BD slot takes an expansion board directly on the CPU: KB6-CAN (CANopen master), KB6-2COM (RS-232 + RS-485), KB6-4DI or KB6-4DO. On top, up to 14 expansion modules connect to the local bus. The CPU supplies them with up to 1500 mA at 5 V and 360 mA at 24 V. From about 7 modules, or when the current budget runs out, you add the K680 power supply to the module row.
💻 Programming and memory
You program the controller with KincoBuilder (IEC 61131-3) in ladder diagram (LD) or instruction list (IL), version V8.5.0.3 or later. The CPU offers 8k instructions of program memory and 20 kB of data memory (16 kB V area, 4 kB M area). 1000 standard instructions execute in 0.3 ms. On top come 256 timers, 256 counters, arrays with up to 1024 elements and a battery-backed real-time clock (deviation below 5 min per month at 25 °C). The V area and counter values are retained on power loss, and the battery is replaceable.
🔗 Compatible with Kinco K5
Terminal layout and power connection match the K5 series, existing K5 programs run without changes, and K5 expansion modules plug in directly. This lets you replace a K5 in the cabinet without rewiring or reprogramming.
🏷️ Manufacturer and standards
Kinco Automation, based in Shanghai and Shenzhen, develops controllers, HMIs and drive technology for international machine builders. The K606-24 is CE marked (EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019) and tested to GB/T 15969.3-2007, which is equivalent to IEC 61131-2:2007. Protection class IP20, operation from −10 °C to +55 °C, 10 % – 95 % relative humidity without condensation, altitude up to 2000 m.
🔧 Mounting
On 35 mm DIN rail or with M4 screws on the mounting plate. Dimensions 128 mm × 114 mm × 76 mm, the terminal blocks are pluggable.
- Available
- Delivery Time : 3 bis 5 Tage
- Product Benefits 1: 14 DI / 10 DO, expandable
- Product Benefits 2: Modbus TCP & RTU
- Product Benefits 3: 4 × HSC up to 200 kHz
- Product Benefits 4: up to 14 expansion modules
- Product Benefits 5: runs K5 programs directly
Available in 30 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Your system has more sensors and actuators than a compact PLC with 24 channels can handle? The Kinco K608-40 comes with 24 digital inputs and 16 outputs, plus two BD slots for CAN, additional interfaces or I/O. Many machines manage without a single expansion module.
🏭 Typical applications
Multi-station machines: assembly, test and packaging lines with many limit switches, light barriers and valves.
Drives via CANopen: with the KB6-CAN board you control up to 64 CANopen nodes, or Kinco servo and stepper drives via the Kinco motion protocol.
Positioning: the transistor variants output pulse and direction on four channels, three of them up to 200 kHz.
Building services: pumps, ventilation and inverters via Modbus RTU, visualisation via Modbus TCP.
⚙️ Four variants
K608-40DT: 24 V DC supply, 16 PNP transistor outputs
K608-40AT: 100 – 240 V AC supply, 16 PNP transistor outputs
K608-40DR: 24 V DC supply, 16 relay outputs
K608-40AR: 100 – 240 V AC supply, 16 relay outputs
💡 The relay variants have no pulse outputs. For positioning tasks, choose DT or AT.
⚡ Inputs and outputs
24 digital inputs 24 V DC, wired as PNP or NPN, optically isolated, input delay below 40 µs (high-speed channels below 5 µs).
PNP transistor outputs: 500 mA per channel at 24 V DC, protected against short circuit, inductive loads and reverse polarity.
Relay outputs: 2 A per contact at 30 V DC or 250 V AC, max. 8 A per group of 4 channels, electrical life 100 000 operations at rated load.
High-speed counters: 4 channels, HSC0 and HSC1 up to 200 kHz, HSC2 and HSC3 up to 20 kHz single-phase or 10 kHz A/B. 4 edge interrupts on I0.0 to I0.3.
Pulse outputs (transistor variants only): 4 channels for PTO (pulse/direction) and PWM, PTO0 to PTO2 up to 200 kHz, PTO3 up to 10 kHz. Positioning instructions and a follow function are included in KincoBuilder.
🔌 Communication
Ethernet 10/100 Mbit/s: Modbus TCP client and server, free communication via TCP and UDP, program upload/download and firmware update over the network.
2 × RS-485, galvanically isolated: 1200 to 115 200 bit/s, Modbus RTU master or slave, free protocol and programming on both ports. Up to 32 devices per port.
🧩 Expansion
Two BD slots take expansion boards directly on the CPU. BD0 accepts communication and I/O boards (KB6-CAN, KB6-2COM, KB6-4DI, KB6-4DO), BD1 accepts I/O boards only (KB6-4DI, KB6-4DO). On top, up to 14 expansion modules connect to the local bus. The CPU supplies them with up to 1500 mA at 5 V and 360 mA at 24 V. From about 7 modules, or when the current budget runs out, you add the K680 power supply to the module row.
💻 Programming and memory
You program the controller with KincoBuilder (IEC 61131-3) in ladder diagram (LD) or instruction list (IL), version V8.5.0.3 or later. The CPU offers 8k instructions of program memory and 20 kB of data memory (16 kB V area, 4 kB M area). 1000 standard instructions execute in 0.3 ms. On top come 256 timers, 256 counters, arrays with up to 1024 elements and a battery-backed real-time clock (deviation below 5 min per month at 25 °C). The V area and counter values are retained on power loss, and the battery is replaceable.
🔗 Compatible with Kinco K5
Terminal layout and power connection match the K5 series, existing K5 programs run without changes, and K5 expansion modules plug in directly. This lets you replace a K5 in the cabinet without rewiring or reprogramming.
🏷️ Manufacturer and standards
Kinco Automation, based in Shanghai and Shenzhen, develops controllers, HMIs and drive technology for international machine builders. The K608-40 is CE marked (EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019) and tested to GB/T 15969.3-2007, which is equivalent to IEC 61131-2:2007. Protection class IP20, operation from −10 °C to +55 °C, 10 % – 95 % relative humidity without condensation, altitude up to 2000 m.
🔧 Mounting
On 35 mm DIN rail or with M4 screws on the mounting plate. Dimensions 186 mm × 114 mm × 76 mm, the terminal blocks are pluggable.
- Available
- Delivery Time : 2-5 days
- Product Benefits 1: 24 DI / 16 DO
- Product Benefits 2: Modbus TCP & RTU
- Product Benefits 3: 2 BD slots
- Product Benefits 4: 4 × HSC up to 200 kHz
- Product Benefits 5: runs K5 programs directly
Your machine needs to measure pressures, temperatures or levels and drive an inverter via an analog signal, not just switch? The Kinco K606EA-30DT already has 4 analog inputs and 2 analog outputs on board. You save the first analog module and still keep all 14 expansion positions.
🏭 Typical applications
Pressure and flow control: connect 4 – 20 mA transmitters directly, including 2-wire sensors, and calculate the control output in your program.
Inverters with analog setpoint: an analog output with 0 – 10 V or 4 – 20 mA sets the speed, the digital outputs switch enable and direction.
Heating, cooling, dosing: temperature and level monitoring with limit alarms without an extra analog module.
Positioning tasks: 4 pulse outputs for stepper and servo drives, three of them up to 200 kHz.
⚡ Inputs and outputs
14 digital inputs 24 V DC, wired as PNP or NPN, optically isolated, input delay below 40 µs (high-speed channels below 5 µs).
10 PNP transistor outputs: 500 mA per channel at 24 V DC, protected against short circuit, inductive loads and reverse polarity.
4 analog inputs: 4 – 20 mA, 0 – 20 mA, 1 – 5 V and 0 – 10 V, 12-bit resolution, accuracy 0.3 % of full scale, about 30 conversions per second and channel. A red LED indicates an out-of-range value.
2 analog outputs: 4 – 20 mA, 0 – 20 mA, 1 – 5 V and 0 – 10 V, 12 bit, accuracy 0.3 % of full scale, load up to 500 Ω in current mode, at least 1 kΩ in voltage mode.
High-speed counters: 4 channels, HSC0 and HSC1 up to 200 kHz, HSC2 and HSC3 up to 20 kHz single-phase or 10 kHz A/B. 4 edge interrupts on I0.0 to I0.3.
Pulse outputs: 4 channels for PTO (pulse/direction) and PWM, PTO0 to PTO2 up to 200 kHz, PTO3 up to 10 kHz.
24 V DC supply; the device provides 300 mA at 24 V for sensors.
🔌 Communication
Ethernet 10/100 Mbit/s: Modbus TCP client and server, free communication via TCP and UDP, program upload/download and firmware update over the network.
2 × RS-485, galvanically isolated: 1200 to 115 200 bit/s, Modbus RTU master or slave, free protocol and programming on both ports. Up to 32 devices per port.
🧩 Expansion
Two BD slots take expansion boards directly on the CPU. BD0 accepts communication and I/O boards (KB6-CAN, KB6-2COM, KB6-4DI, KB6-4DO), BD1 accepts I/O boards only (KB6-4DI, KB6-4DO). On top, up to 14 expansion modules connect to the local bus. The CPU supplies them with up to 1500 mA at 5 V and 360 mA at 24 V. From about 7 modules, or when the current budget runs out, you add the K680 power supply to the module row.
💻 Programming and memory
You program the controller with KincoBuilder (IEC 61131-3) in ladder diagram (LD) or instruction list (IL), version V8.5.0.3 or later. The CPU offers 8k instructions of program memory and 20 kB of data memory (16 kB V area, 4 kB M area). 1000 standard instructions execute in 0.3 ms. On top come 256 timers, 256 counters, arrays with up to 1024 elements and a battery-backed real-time clock (deviation below 5 min per month at 25 °C). The V area and counter values are retained on power loss, and the battery is replaceable.
🔗 Compatible with Kinco K5
Terminal layout and power connection match the K5 series, existing K5 programs run without changes, and K5 expansion modules plug in directly. This lets you replace a K5 in the cabinet without rewiring or reprogramming.
🏷️ Manufacturer and standards
Kinco Automation, based in Shanghai and Shenzhen, develops controllers, HMIs and drive technology for international machine builders. The K606EA-30DT is CE marked (EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019) and tested to GB/T 15969.3-2007, which is equivalent to IEC 61131-2:2007. Protection class IP20, operation from −10 °C to +55 °C, 10 % – 95 % relative humidity without condensation, altitude up to 2000 m.
🔧 Mounting
On 35 mm DIN rail or with M4 screws on the mounting plate. Dimensions 186 mm × 114 mm × 76 mm, the terminal blocks are pluggable.
- Available
- Delivery Time : 2-5 days
- Product Benefits 1: 4 AI / 2 AO, 12 bit
- Product Benefits 2: Modbus TCP & RTU
- Product Benefits 3: 4 × PTO/PWM up to 200 kHz
- Product Benefits 4: 2 BD slots
- Product Benefits 5: up to 14 expansion modules
Full-featured, fast expandable and very compact PLC from XINJE at a tiger price with 16 inputs and 16 outputs. Versatile feature set for simple control, positioning and regulation tasks. Ideally suited for simple machines, devices and plant controls, also where fast PLC cycles are needed. The PLC is programmed in ladder diagram (LD) or instruction list (IL).
- Available
- Delivery Time : 3 bis 5 Tage
- Product Benefits 1: Ethernetschnittstelle
- Product Benefits 2: kompaktes Design
- Product Benefits 3: erweiterbar
4 digital inputs 24 VDC (PNP)
1 x RS-485 (Modbus RTU) + 1 x RS-232 (programming port) + 1 x Ethernet + 2 x CANopen
You can program this compact Kinco KS-PLC with the free Kinco-Builder programming software (available as download a little further down on this page).
Scope of supply: PLC.
- Available
- Delivery Time : 6 bis 8 Wochen
- Product Benefits 1: 4 x Digitaleingang (24 VDC, PNP)
- Product Benefits 2: 1 x Ethernet
- Product Benefits 3: 2 x CANopen
- Product Benefits 4: erweiterbar (max. 14 Module)
8 digital inputs 24 VDC (PNP)
6 digital outputs transistor 24 VDC1 x analog input 0/4 - 20 mA / 0 - 10 V1 x analog output 0/4- 20 mA / 0 - 10 V1 x Ethernet (RJ45)2 x RS-485 (Modbus RTU)
You can program the Kinco K2 with the free Kinco-Builder programming software (available as a download further down on this page).
Scope of delivery: PLC
- Available
- Delivery Time : 3-4 weeks
- Product Benefits 1: Ethernet
- Product Benefits 2: 8 Digital input 24 VDC
- Product Benefits 3: 6 Digital output transistor
- Product Benefits 4: 1 analog input
- Product Benefits 5: 1 analog output