Do you have questions? Our community may have already answered them!
Connect with others in our support forum.
Odot CN-8032 – PROFINET bus coupler for remote I/O, up to 32 I/O modules
- up to 32 I/O modules
- 11 fieldbuses to choose
- Push-in terminals, DIN rail
- −35 °C to +70 °C
€167.94*
% €167.94* (0% saved)Available in 14 days, delivery time 3 bis 5 Tage
Required accessory
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Matching I/O modules
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Alternative
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Customers also viewed
Customers also viewed
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Do you want to run the I/O modules of the Odot C series not right next to the PLC, but distributed at the machine or in a sub-distribution? Then put a bus coupler in front of them. It connects up to 32 C-series modules via the fieldbus of your controller, whether your PLC comes from Siemens, Beckhoff, Kinco, Odot or another manufacturer. You just choose the coupler with the matching fieldbus.
🏭 Typical applications
Distributed I/O at the machine: sensors and actuators are wired on site, only one network or bus cable runs to the PLC.
Expanding existing plants: if a Siemens or Beckhoff controller is short of channels, you add them via PROFINET, EtherCAT or PROFIBUS without replacing the PLC.
Together with the Odot C4374: the C4374 is a master for Modbus TCP, Modbus RTU, EtherCAT and CANopen. The matching couplers are CN-8031, CN-8011, CN-8033 and CN-8021. This lets you build additional I/O stations controlled by the PLC.
Building automation and control systems: with BACnet/IP or Modbus TCP the modules deliver their data directly to BMS or SCADA systems.
🌐 Available fieldbuses
Modbus RTU (CN-8011) · PROFIBUS DP (CN-8012) · CANopen (CN-8021) · DeviceNet (CN-8022) · Modbus TCP (CN-8031) · PROFINET with MRP (CN-8032) · PROFINET without MRP (CN-8032-L) · EtherCAT (CN-8033) · EtherNet/IP (CN-8034) · POWERLINK (CN-8035) · BACnet/IP (CN-8038). The Ethernet versions have 2 RJ45 ports (10/100 Mbit/s) for daisy-chaining in line topology.
💡 Device description files: the matching GSD, GSDML, EDS or XDD files for integration into your PLC software are in the Downloads tab of each coupler. You configure the I/O modules with the free Odot software IO-Config.
🔧 Technical data (all couplers)
Expansion: up to 32 I/O modules of the Odot C series per coupler
Supply: system and field supply 24 V DC, galvanically isolated, with reverse polarity protection; field current max. 8 A
Environment: operation −35 °C to +70 °C for horizontal, −35 °C to +60 °C for vertical mounting; storage −40 °C to +85 °C; protection class IP20
Mounting: 35 mm DIN rail, push-in terminals, dimensions 51.5 × 115 × 75 mm (W × H × D), 130 g
⚠️ Don't forget the end module: every station needs an end module CT-5801 at its end. It is not included with the bus coupler, please order it as well.
🏷️ Manufacturer
Odot Automation (Sichuan Odot Automation System Co., Ltd.) specialises in IEC 61131-3 controllers and distributed I/O systems. The bus couplers are part of the C-series system and work with all digital, analog, temperature and special modules of the series.
Technical Specifications
0 of 0 reviews
Login
Aktive Kühlung oder Lüfter bedeutet, das Gerät hat einen eingebauten Lüfter zur Kühlung. Ein aktiver Lüfter verursacht zusätzliche Geräuschemissionen.
PROFINET / EtherCAT / EtherNet/IP: Real-time capable Ethernet protocols – direct connection to Siemens S7, Beckhoff TwinCAT, Allen-Bradley and others.
Modbus TCP/RTU: Simple, open standard – supported by virtually every PLC and many frequency inverters.
The protocol determines which controller can integrate the module directly without a gateway.
Overcurrent / short-circuit protection: Shuts down during overload without permanent damage.
Galvanic isolation: Electrical decoupling between supply and signal circuit – prevents ground loop problems.
Sensor disconnection detection: Reports when a sensor does not provide a valid value or the line is interrupted.
IP20: Protection against finger contact – no dust or water protection. Standard for control cabinet installation.
IP67: Fully dustproof and waterproof during temporary submersion (1 m, 30 min). Suitable for field mounting directly on machines.
RoHS: Restriction of hazardous substances – no lead, mercury, cadmium etc. (EU Directive 2011/65/EU).
REACH: Registration, evaluation and restriction of chemical substances in the EU.
UL: American testing mark (Underwriters Laboratories) – relevant for the US market.
EMC standards (EN 61000-6-x): Confirm electromagnetic compatibility for industrial use.
Screw terminal: Classic connection with a screwdriver – universally familiar, easy to retighten, proven in practice.