Do you have questions? Our community may have already answered them!
Connect with others in our support forum.
Odot CT-3713 – 3 temperature inputs Pt100, C series
- 3 to 8 channels
- Pt100, Pt1000, thermocouple
- Push-in spring terminals
- For C3351, C4374 & CN couplers
€98.00*
% €98.00* (0% saved)Compatible PLCs
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
More from the series
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
End module
Available in 14 days, delivery time 3 bis 5 Tage
Preis exkl. MwSt., zzgl. Versandkosten
Customers also bought
Customers also bought
Customers also viewed
Customers also viewed
Measure temperature directly at the controller – without separate transmitters: the temperature modules of the Odot C series connect resistance thermometers and thermocouples directly. Pick sensor type and channel count to suit your plant.
🏭 Typical applications
- Pt100: CT-3713 with 3 inputs or CT-3734 with 4 isolated inputs.
- Pt1000: CT-3723 with 3 inputs, CT-3744 with 4 isolated inputs or CT-3726 with 6 inputs.
- Thermocouples for high temperatures: CT-3844 with 4 and CT-3848 with 8 inputs, type J, K, E, T, S, R, B and N.
Channel-isolated modules pay off when sensors sit on different potentials or interference on one channel must not affect the others.
🔌 Compatible with
- Odot C3351 and C4374 PLC (CODESYS 3.5), up to 32 modules directly to the right of the CPU
- Odot CN bus couplers for remote I/O – PROFINET, EtherCAT, EtherNet/IP, Modbus TCP/RTU, CANopen and more
📐 Common data
- Push-in spring terminals, 35 mm DIN rail
- IP20, system bus supplied by the PLC or bus coupler
Important: every module string – on the C3351 / C4374 PLC or on a CN bus coupler – ends with the CT-5801 end module. Odot lists it as a mandatory module.
Technical Specifications
0 of 0 reviews
Login
Aktive Kühlung oder Lüfter bedeutet, das Gerät hat einen eingebauten Lüfter zur Kühlung. Ein aktiver Lüfter verursacht zusätzliche Geräuschemissionen.
IP20: Protection against finger contact – no dust or water protection. Standard for control cabinet installation.
IP67: Fully dustproof and waterproof during temporary submersion (1 m, 30 min). Suitable for field mounting directly on machines.
RTD – Resistance Temperature Detectors (Pt100, Pt1000 etc.): Measure temperature via the temperature-dependent resistance – more accurate and stable than thermocouples.
RES: Direct resistance measurement (15 Ω to 3 kΩ).
Screw terminal: Classic connection with a screwdriver – universally familiar, easy to retighten, proven in practice.