Create PDF quotation for this product
Hint: You can add multiple products to the cart and create a quotation in the cart. For logged in users the link will generate a quotation with their address.
Product information "Kinco G070E-CAN 7" Green Series Widescreen HMI Touch Panel with CANopen Slave support"
The G070E-CAN is a modern, versatile and very cost-effective HMI touch panel with 7'' screen diagonal and a resolution of 800 * 480 pixels from Kinco with Ethernet interface and CANopen Slave interface.
The HMI is programmed via the free software Kinco DTools. You can find this further down on this page as a download. The software is available in German language.
Manufacturer "Kinco"
Kinco is one of the leading manufacturers of automation technology in Asia. The company's research and development team is based at its headquarters in Shenzhen (China) on the border with Hong Kong, and Kinco also operates a research center in Germany, a unique feature among Chinese companies.
In terms of quality and range of functions, Kinco is strongly oriented towards the European and German markets. Communication drivers for Siemens S7 controllers are therefore included in every HMI. The company has a modern and reliable range of HMIs, drive technology and controllers. Kinco already generates more than 10% of its turnover internationally, and Germany is one of the manufacturer's growth markets.
1 x USB host (for USB memory, keyboard, webcam, barcode reader, etc.)
USB slave connections:
1 x USB slave (program download only)
VPN:
Integrated VPN function for remote control and remote maintenance
Dimensions and environmental properties
Brightness:
400 cd/m²
Cooling:
Ambient air (passive)
Depth:
34 mm
Dimensions (Width x Height x Depth):
204 mm x 150 mm x 35 mm
Height:
150 mm
Housing Material:
Engineering plastic
Mounting:
Slide-in unit (e.g. switch cabinet door with clips from behind)
Mounting Detail:
192 mm x 138 mm cut-out; 32 mm depth after installation, mounting brackets supplied
Operating Temperature Range:
0 °C to +50 °C
Protection Rating:
IP65 (front)
Storage Temperature Range:
-20 °C to +60 °C
Weight:
0.5 kg
Width:
204 mm
Other properties
Data logger:
Yes
Memory:
128 MB DDR3 RAM memory , 128 MB NAND flash memory
Product Series:
Green Series
Real-time clock:
Yes (synchronization with network time possible)
Year of market launch:
2019
Programming
Language of the programming environment:
Arabic , Chinese , English , German , Korean , Russian , Turkish
Programming languages:
C (standard C) for macros , Graphical programming interface
Programming software:
Kinco DTools
Certifications
CE Certificate:
Yes
Standards and Certifications:
CE (EN61000-6-4:2007+A1:2011, EN61000-6-2:2005)
0 of 0 reviews
Leave a review!
Share your experiences with other customers.
Login
Login or Register with...
No reviews found. Share your insights with others.
Kinco DTools
Kinco DTools ist die kostenfreie Programmiersoftware für die Kinco HMI. Hier findet ihr die passenden Downloads.
Brightness
The brightness in cd/m² indicates the maximum brightness of the display. An average laptop has a brightness of around 250 cd/m², which is generally sufficient for artificially lit rooms such as offices or production halls. For very bright rooms with a lot of daylight, 350 cd/m² or more is recommended. Displays with 800 cd/m² or more are required for good readability in direct sunlight, but these are generally significantly more expensive than standard displays.
Kühlung
Passive Kühlung (Umgebungsluft) bedeutet, das Gerät hat keine aktiven Lüfter, sondern kühlt sich selbst. Achten Sie darauf, dass das Gerät den Einbauabstand zu Seiten und Rückwänden einhält, um einen Wärmestau zu vermeiden.
Aktive Kühlung oder Lüfter bedeutet, das Gerät hat einen eingebauten Lüfter zur Kühlung. Ein aktiver Lüfter verursacht zusätzliche Geräuschemissionen.
Fieldbus and Communication Protocols
Fieldbuses are industrial network standards for real-time communication between PLCs, I/O modules, sensors and actuators.
PROFINET / EtherCAT / EtherNet/IP: Real-time capable Ethernet protocols – direct connection to Siemens S7, Beckhoff TwinCAT, Allen-Bradley and others. Modbus TCP/RTU: Simple, open standard – supported by virtually every PLC and many frequency inverters.
The protocol determines which controller can integrate the module directly without a gateway.
Galvanic Isolation of the Serial Interface
A galvanically or optically isolated interface interrupts the conductive connection between the module and the connected device. This prevents equalising currents via ground loops that can cause interference or damage.
Particularly important when devices operate at different potential levels or when long cable runs are installed.
Isolierte Spannungsversorgung
Eine isolierte Spannungsversorgung reduziert elektromagnetische Störungen vor allem auf seriellen Anschlüssen wie RS-232 oder RS-485 des Geräts. Damit wird die Störfestigkeit der Kommunikation erhöht.
MQTT
MQTT ist ein Austauschprotokoll, das vor allem im IoT-Bereich beliebt ist. Es ermöglicht den Austausch von Werten und Meldungen über einen sogenannten MQTT-Broker, der diese Nachrichten an abonnierende Systeme verteilt. Es kann vor allem für den offenen Austausch von Informationen zwischen Maschinen genutzt werden.
The permissible voltage range indicates the input voltage range within which the device can be operated safely and reliably. Make sure the input voltage does not fluctuate significantly, as this could negatively affect device operation.
Protection Rating per IP Standard (IEC 60529)
The IP designation (Ingress Protection) indicates how well a device is protected against contact, dust and water.
IP20: Protection against finger contact – no dust or water protection. Standard for control cabinet installation. IP67: Fully dustproof and waterproof during temporary submersion (1 m, 30 min). Suitable for field mounting directly on machines.
CE, RoHS and Further Certifications
CE: Mandatory marking for the European market – confirms compliance with all relevant EU directives (EMC, Low Voltage, RoHS). RoHS: Restriction of hazardous substances – no lead, mercury, cadmium etc. (EU Directive 2011/65/EU). REACH: Registration, evaluation and restriction of chemical substances in the EU. UL: American testing mark (Underwriters Laboratories) – relevant for the US market. EMC standards (EN 61000-6-x): Confirm electromagnetic compatibility for industrial use.
This website uses cookies to ensure the best experience possible. More information...